Changes between Version 1 and Version 2 of HetProcedures/TO/selfstack
- Timestamp:
- Dec 1, 2018 5:21:33 AM (5 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
HetProcedures/TO/selfstack
v1 v2 1 1 = Self Stacking 2 2 3 It is important during self stacking that the HET shutter and CCAS tower remain closed. Do '''NOT''' open these shutters during this procedure. 3 It is important during self stacking that the HET shutter and CCAS tower remain closed. Do '''NOT''' open these shutters during this procedure. This is the procedure used for checking the operation and functionality of the wavescope along with the AOA software. 4 4 5 5 == … … 18 18 6.) Follow the prompts as if they are for the reference shutter and make sure to click ok for the script to continue. 19 19 20 7.) Wait for the mirror RSE to be within 100 of the Target RSE and tip/tilt to be less than 0.3 21 22 8.) If you wish to stack multiple times just run another ''S0'' command and repeat step 6 and 7. 23 24 9.) When you are done stacking, make sure to close the reference shutter and to turn off the wavescope in the APC GUI. 20 9.) When you are done checking the AOA and Wavescope, make sure to close the reference shutter and to turn off the wavescope in the APC GUI.