    33== Compressor Inspection and Startup Procedure
    4 1.)
     41.) Structure Air Compressor - Quincy
     5 * The Structure Air Compressor and Dryer can be in one of two states depending on the position of the yellow -handled valve and power setting on the air dryer. Dryer Power Off and Valve Shut - '''System in OFF State'''
     6
     7  a.) Assuming the correct shutdown procedure was followed (red button on compressor control panel not pushed in).
     8
     9  b.) Start opening the yellow-handled valve (from horizontal to vertical position) but very slowly in case there is a pressure differential between the inlet and outlet of the air dryer.
     10
     11  c.) To start up the system, turn on power to the air dryer by pressing the black button on the control panel labeled "ON". This will start the dryer cycle. Shortly after pressing the button, air will vent from one of the dryer towers. Expect to hear a very loud "WUSH" sound as air releases from the tower.
     12
     13  d.) Depending on the pressure upstream from the dryer, the compressor may start up immediately or a few minutes later when the pressure has dropped below the startup threshold. Look at the pressure reading on the pressure gauge located the left side of the receiver tank behind the compressor. The compressor should start up automatically when the pressure drops below approximately 100psi.
     14 
     15  e.) After checking the pressure on the Quincy, check the lights for all the components on the Quincy to the left of the pressure meters. Make sure all lights are responding, and if not be sure to notify the mechanical team so they can replace the burnt out bulb.
     16
     17  f.) The final check on the Quincy is the oil, which is located at the top of the far left blue cylinder. If there looks to be no oil at all, contact the mechanical team.
     18
     19 * Dryer Power On and Valve Open - '''System is ON State'''
     20
     21   a.) If the power to the dryer is on, the black button on the control panel on the front of the dryer is depressed and the yellow-handle valve on the air dryer is open, the system is already in the ON state.