    5656  '''Note''': If you have to leave the facility for some reason and the night TO is not there yet, do not leave SAMS in open loop form. Place it on standby with SCS moved to none.
    5757
     58=== Check Wavescope Focus
     591.) In the TCS GUI under the APC status control, turn on the wavescope button which is in the CCAS section.
     60
     612.) In the MARS GUI make sure the AOA shutters are open.
     62
     633.) Navigate to the wavescope/AOA computer. Turn on the wavescope software.
     64
     654.) Under Alignment tab select manual and choose the very last file. Swap between pupil and shutter mode to make sure stacking will be possible that night. If stacking does not look possible, make sure to contact an engineer to adjust the focus from the CCAS tower.
     66
     675.) Once you are done exit out of the wavescope software, closing the image windows as well.
     68
     696.) Over in APC make sure to turn the wavescope off and in MARS to close the shutter.