Changes between Version 7 and Version 8 of TOManual/stack2


Ignore:
Timestamp:
Dec 22, 2018 12:31:29 PM (5 years ago)
Author:
ccrowe
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • TOManual/stack2

    v7 v8  
    3131MARS FOCUS.  There are two places to read these values.  One is in the window that was calculating the focus curve and the other is in the Hefi Focus Curve GUI on the bottom.  Take the better of the two.  An ee50 below 0.65 is satisfactory.  If that value is above 0.65 and the weather conditions were not binding, you should go back and do a few more iterations if there is time. NOTE this time as the FINISHED TIME.  (If this is the first stack of the night, the end time should be before 18 degree).
    3232
    33 NOTE: If you are taking a post-observation stack, skip to step 10.
     33'''NOTE: If you are taking a post-observation, skip to step 10.'''
    3434
    35358) Once you're finished with the iterations, press the image sequence button on HEFI (leave light in and on low). In the window that pops up, change the name of the sequence to sequenceX where X is the number of the stack (e.g. sequence2 for the second stack, etc.). Then change the number in the start box to 1, count to 30, and delay to 2. Press start and wait for the window to say 'IDLE'.