| 3 | == Missing mirrors in the reference measurement of AOA == |
| 4 | |
| 5 | The ultimate goal here is for the mirror locations for each mirror to be |
| 6 | in a file called mirror_locations.txt on the wave computer in the location |
| 7 | C:\aoa\mirror_locations.txt. |
| 8 | |
| 9 | Step 1: Obtain a spot image of the reference grid. |
| 10 | - under the wavescope software go to the menu selection |
| 11 | Alignment->Manual, select the "Show Spot Image" under the |
| 12 | Reference Source. |
| 13 | - snap an image using the command "snap <filename>" |
| 14 | (this will save the image in E:<filename>.fits) |
| 15 | |
| 16 | Step 3: Check spot locations |
| 17 | - ds9 /home/mars/guider/wave/<filename>.fits |
| 18 | - see if the spot locations are close to existing mirror_locations.txt. |
| 19 | - you may want to copy over the mirror_locations.txt to E as well to make this go faster. |
| 20 | |
| 21 | Step 4: Create new spot locations if needed |
| 22 | - (iraf stuff) |
| 23 | |
| 24 | Step 5: Copy the new mirror_locations.txt to the AOA software directory |
| 25 | - place a copy of the new file in /home/mars/guider/wave/mirror_locations.txt and /home/mars/guider/wave/mirror_locations_YYYYMMDD.txt |
| 26 | - go to the wave computer, open up the shortcut to aoa |
| 27 | - rename the current mirror_locations.txt to mirror_locations.txt-old |
| 28 | - navigate to the E: drive, copy the two new files to the aoa directory |
| 29 | |
| 30 | Step 6: restart the wavescope software if needed. |